https://issues.apache.org/jira/browse/FLINK-9936?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16568132#comment-16568132
 ] 

ASF GitHub Bot commented on FLINK-9936:
---------------------------------------

GJL commented on issue #6464: [FLINK-9936][mesos] Mesos resource manager unable 
to connect to master after failover 
URL: https://github.com/apache/flink/pull/6464#issuecomment-410232380
 
 
   @liurenjie1024 Do you also want to have final look? The fix works in my 
cluster tests.

----------------------------------------------------------------
This is an automated message from the Apache Git Service.
To respond to the message, please log on GitHub and use the
URL above to go to the specific comment.
 
For queries about this service, please contact Infrastructure at:
us...@infra.apache.org


> Mesos resource manager unable to connect to master after failover
> -----------------------------------------------------------------
>
>                 Key: FLINK-9936
>                 URL: https://issues.apache.org/jira/browse/FLINK-9936
>             Project: Flink
>          Issue Type: Bug
>          Components: Mesos, Scheduler
>    Affects Versions: 1.5.0, 1.5.1, 1.6.0
>            Reporter: Renjie Liu
>            Assignee: Gary Yao
>            Priority: Blocker
>              Labels: pull-request-available
>             Fix For: 1.5.3, 1.6.0
>
>
> When deployed in mesos session cluster mode, the connector monitor keeps 
> reporting unable to connect to mesos after restart. In fact, scheduler driver 
> already connected to mesos master, but when the connected message is lost. 
> This is because leadership is not granted yet and fence id is not set, the 
> rpc service ignores the connected message. So we should connect to mesos 
> master after leadership is granted.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to