https://issues.apache.org/jira/browse/FLINK-9932?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Chesnay Schepler updated FLINK-9932:
------------------------------------
Summary: If task executor offers slot to job master timeout the first time,
the slot will leak (was: If task executor offer slot to job master timeout the
first time, the slot will leak)
> If task executor offers slot to job master timeout the first time, the slot
> will leak
> -------------------------------------------------------------------------------------
>
> Key: FLINK-9932
> URL: https://issues.apache.org/jira/browse/FLINK-9932
> Project: Flink
> Issue Type: Bug
> Components: Cluster Management
> Affects Versions: 1.5.0
> Reporter: shuai.xu
> Assignee: shuai.xu
> Priority: Blocker
> Labels: pull-request-available
> Fix For: 1.5.5, 1.6.2, 1.7.0
>
>
> When task executor offer slot to job master, it will first mark the slot as
> active.
> If the offer slot call timeout, the task executor will try to call
> offerSlotsToJobManager again,
> but it will only offer the slot in ALLOCATED state. As the slot has already
> be mark ACTIVE, it will never be offered and this will cause slot leak.
--
This message was sent by Atlassian JIRA