Nico Kruber created FLINK-10727:
-----------------------------------
Summary: Remove unnecessary synchronization in
SingleInputGate#requestPartitions()
Key: FLINK-10727
URL: https://issues.apache.org/jira/browse/FLINK-10727
Project: Flink
Issue Type: Improvement
Components: Network
Affects Versions: 1.6.2, 1.5.5, 1.7.0
Reporter: Nico Kruber
Assignee: Nico Kruber
For every {{SingleInputGate#getNextBufferOrEvent()}},
{{SingleInputGate#requestPartitions()}} is called and this always synchronizes
on the {{requestLock}} before checking the {{requestedPartitionsFlag}}. Since
{{SingleInputGate#requestPartitions()}} is only called from the same thread
(the task thread getting the record), it is enough to check the
{{requestedPartitionsFlag}} first before synchronizing for the actual requests
(if needed). {{UnionInputGate}} already goes the same way in its
{{requestPartitions()}} implementation.
--