https://issues.apache.org/jira/browse/FLINK-14848?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Zhenghua Gao updated FLINK-14848:
---------------------------------
Description:
Take non-compact decimal(precision > 18 null as an example, the writer not only
need to set null bits, but also need to assign bytes of variable-length part
for future update. The following test case can reproduce the problem.
{code:java}
@Test
public void test() {
Decimal dec = Decimal.fromBigDecimal(new BigDecimal(11), 38, 0);
BinaryRow row1 = new BinaryRow(2);
BinaryRowWriter writer = new BinaryRowWriter(row1);
writer.writeDecimal(0, dec, 38);
writer.writeDecimal(1, null, 38);
writer.complete();
BaseRowSerializer serializer = new BaseRowSerializer(null, RowType.of(new
DecimalType(38, 0), new DecimalType(38, 0)));
GenericRow row2 = new GenericRow(2);
row2.setField(0, dec);
row2.setField(1, null);
BinaryRow row3 = serializer.toBinaryRow(row2);
assertTrue(row1.equalsWithoutHeader(row3));
}
{code}
was:
Take non-compact decimal(precision > 18 null as an example, the writer not only
need to set null bits, but also need to assign bytes of variable-length part
for future update. The following test case can reproduce the problem.
@Test
public void test() {
Decimal dec = Decimal.fromBigDecimal(new BigDecimal(11), 38, 0);
BinaryRow row1 = new BinaryRow(2);
BinaryRowWriter writer = new BinaryRowWriter(row1);
writer.writeDecimal(0, dec, 38);
writer.writeDecimal(1, null, 38);
writer.complete();
BaseRowSerializer serializer = new BaseRowSerializer(null, RowType.of(new
DecimalType(38, 0), new DecimalType(38, 0)));
GenericRow row2 = new GenericRow(2);
row2.setField(0, dec);
row2.setField(1, null);
BinaryRow row3 = serializer.toBinaryRow(row2);
assertTrue(row1.equalsWithoutHeader(row3));
}
> BaseRowSerializer.toBinaryRow wrongly process null for objects with
> variable-length part
> ----------------------------------------------------------------------------------------
>
> Key: FLINK-14848
> URL: https://issues.apache.org/jira/browse/FLINK-14848
> Project: Flink
> Issue Type: Bug
> Components: Table SQL / Planner
> Affects Versions: 1.9.1
> Reporter: Zhenghua Gao
> Priority: Major
>
> Take non-compact decimal(precision > 18 null as an example, the writer not
> only need to set null bits, but also need to assign bytes of variable-length
> part for future update. The following test case can reproduce the problem.
>
>
> {code:java}
> @Test
> public void test() {
> Decimal dec = Decimal.fromBigDecimal(new BigDecimal(11), 38, 0);
> BinaryRow row1 = new BinaryRow(2);
> BinaryRowWriter writer = new BinaryRowWriter(row1);
> writer.writeDecimal(0, dec, 38);
> writer.writeDecimal(1, null, 38);
> writer.complete();
> BaseRowSerializer serializer = new BaseRowSerializer(null, RowType.of(new
> DecimalType(38, 0), new DecimalType(38, 0)));
> GenericRow row2 = new GenericRow(2);
> row2.setField(0, dec);
> row2.setField(1, null);
> BinaryRow row3 = serializer.toBinaryRow(row2);
> assertTrue(row1.equalsWithoutHeader(row3));
> }
> {code}
>
>
--
This message was sent by Atlassian Jira
(v8.3.4#803005)