JingsongLi commented on a change in pull request #10620:
[FLINK-15239][table-planner-blink] CompileUtils::COMPILED_CACHE leaks class
loaders
URL: https://github.com/apache/flink/pull/10620#discussion_r361271907
##########
File path:
flink-table/flink-table-runtime-blink/src/main/java/org/apache/flink/table/runtime/generated/CompileUtils.java
##########
@@ -45,7 +48,7 @@
* number of Meta zone GC (class unloading), resulting in performance
bottlenecks. So we add
* a cache to avoid this problem.
*/
- protected static final Cache<Tuple2<ClassLoader, String>, Class<?>>
COMPILED_CACHE = CacheBuilder
+ protected static final Cache<String, Cache<ClassLoader, Class>>
COMPILED_CACHE = CacheBuilder
.newBuilder()
.maximumSize(100) // estimated cache size
Review comment:
1. For the execution mode of Flink, the `UserCodeClassLoader` used by each
task may be different.
2. The class from CodeGenerated may contain the dependence on user code
class, which is in `UserCodeClassLoader` of a task.
So, if we ignore class loader, that will lead to errors. Maybe class not
found or class not match.
I don't know the details of Spark and Calcite, but maybe Spark breaks # 2
and Calcite breaks # 1.
----------------------------------------------------------------
This is an automated message from the Apache Git Service.