https://issues.apache.org/jira/browse/FLINK-15549?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

caojian0613 updated FLINK-15549:
--------------------------------
    Affects Version/s:     (was: 1.9.1)
                           (was: 1.9.0)
                       1.10.0

> integer overflow in SpillingResettableMutableObjectIterator
> -----------------------------------------------------------
>
>                 Key: FLINK-15549
>                 URL: https://issues.apache.org/jira/browse/FLINK-15549
>             Project: Flink
>          Issue Type: Bug
>          Components: Runtime / Task
>    Affects Versions: 1.10.0
>            Reporter: caojian0613
>            Priority: Major
>              Labels: overflow
>
> The SpillingResettableMutableObjectIterator has a data overflow problem if 
> the number of elements in a single input exceeds Integer.MAX_VALUE.
> The reason is inside the SpillingResettableMutableObjectIterator, it track 
> the total number of elements and the number of elements currently read with 
> two int type fileds (elementCount and currentElementNum), and if the number 
> of elements exceeds Integer.MAX_VALUE, it will overflow.
> If there is an overflow, then in the next iteration, after reset the input , 
> the data will not be read or only part of the data will be read.
> Therefore, we should changing the type of these two fields of 
> SpillingResettableIterator* from int to long, and we also need a pre-check 
> mechanism before such numerical.



--