Github user rmetzger commented on the pull request:

    https://github.com/apache/flink/pull/1097#issuecomment-158765143
  
    I've tested the PR again. 
    I found a minor issue with the alternative arguments.
    input: `--input abc --p 12`,
    code:
    ```java
    RequiredParameters rq = new RequiredParameters();
                rq.add("input");
                rq.add(new 
Option("parallelism").alt("p").defaultValue("1").type(OptionType.INTEGER));
                ParameterTool pt = ParameterTool.fromArgs(args);
                rq.applyTo(pt);
    
                String in = pt.get("input");
                System.out.println("In = "+in + " parallelism = 
"+pt.getInt("parallelism") + " p="+pt.getInt("p"));
    
                System.exit(0);
    ```
    
    error 
    ```
    Exception in thread "main" java.lang.RuntimeException: No data for required 
key 'p'
        at 
org.apache.flink.api.java.utils.ParameterTool.getRequired(ParameterTool.java:236)
        at 
org.apache.flink.api.java.utils.ParameterTool.getInt(ParameterTool.java:272)
        at 
org.apache.flink.examples.java.wordcount.WordCount.main(WordCount.java:69)
    ```
    
    I think we need to set the (default) value for the long and the short 
variant.


---
If your project is set up for it, you can reply to this email and have your
reply appear on GitHub as well. If your project does not have this feature
enabled and wishes so, or if the feature is enabled but not working, please
contact infrastructure at [email protected] or file a JIRA ticket
with INFRA.
---

Reply via email to