https://issues.apache.org/jira/browse/FLINK-2837?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15033759#comment-15033759
 ] 

ASF GitHub Bot commented on FLINK-2837:
---------------------------------------

Github user mjsax commented on a diff in the pull request:

    https://github.com/apache/flink/pull/1398#discussion_r46284171
  
    --- Diff: 
flink-contrib/flink-storm/src/main/java/org/apache/flink/storm/wrappers/BoltWrapper.java
 ---
    @@ -108,16 +114,13 @@ public BoltWrapper(final IRichBolt bolt, final Fields 
inputSchema)
         * for POJO input types. The output type can be any type if parameter 
{@code rawOutput} is {@code true} and the
         * bolt's number of declared output tuples is 1. If {@code rawOutput} 
is {@code false} the output type will be one
         * of {@link Tuple0} to {@link Tuple25} depending on the bolt's 
declared number of attributes.
    -    * 
    -    * @param bolt
    -    *            The Storm {@link IRichBolt bolt} to be used.
    +    * @param bolt The Storm {@link IRichBolt bolt} to be used.
         * @param rawOutputs
         *            Contains stream names if a single attribute output 
stream, should not be of type {@link Tuple1} but be
         *            of a raw type.
         * @throws IllegalArgumentException
         *             If {@code rawOuput} is {@code true} and the number of 
declared output attributes is not 1 or if
         *             {@code rawOuput} is {@code false} and the number of 
declared output attributes is not with range
    -    *             [1;25].
    --- End diff --
    
    Please keep and update: should be `[0;25]`


> FlinkTopologyBuilder cannot handle multiple input streams
> ---------------------------------------------------------
>
>                 Key: FLINK-2837
>                 URL: https://issues.apache.org/jira/browse/FLINK-2837
>             Project: Flink
>          Issue Type: Bug
>          Components: Storm Compatibility
>            Reporter: Matthias J. Sax
>            Assignee: Maximilian Michels
>
> FlinkTopologyBuilder cannot handle multiple input streams correctly. Instead 
> of union the incoming streams, it replicates the consuming bolt and each 
> (logical) instance processes one of the input streams.
> For example:
> {noformat}
> final FlinkTopologyBuilder builder = new FlinkTopologyBuilder();
> builder.setSpout(spoutId1, new FiniteRandomSpout(0, 10));
> builder.setSpout(spoutId2, new FiniteRandomSpout(1, 8));
> builder.setSpout(spoutId3, new FiniteRandomSpout(2, 13));
> builder.setBolt(boltId, new MergerBolt())
>       .shuffleGrouping(spoutId1)
>       .shuffleGrouping(spoutId2)
>       .shuffleGrouping(spoutId3);
> builder.setBolt("sink", new BoltPrintSink(new SimpleOutputFormatter()))
>       .shuffleGrouping(boltId);
> {noformat}
> will only print the data from a single source instead of all sources.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to