https://issues.apache.org/jira/browse/FLINK-12855?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Aljoscha Krettek closed FLINK-12855.
------------------------------------
Fix Version/s: 1.12.0
Resolution: Fixed
master: b592dd230a4d1b5b8072714ebb099b94596fdac8
Please add more issues if you want to add staggering to other window assigners.
> Stagger TumblingProcessingTimeWindow processing to distribute workload
> ----------------------------------------------------------------------
>
> Key: FLINK-12855
> URL: https://issues.apache.org/jira/browse/FLINK-12855
> Project: Flink
> Issue Type: New Feature
> Components: API / DataStream
> Reporter: Teng Hu
> Assignee: Teng Hu
> Priority: Major
> Labels: pull-request-available
> Fix For: 1.12.0
>
> Attachments: stagger_window.png, stagger_window_delay.png,
> stagger_window_throughput.png
>
> Time Spent: 10m
> Remaining Estimate: 0h
>
> Flink natively triggers all panes belonging to same window at the same time.
> In other words, all panes are aligned and their triggers all fire
> simultaneously, causing the thundering herd effect.
> This new feature provides the option that panes could be staggered across
> partitioned streams, so that their workloads are distributed.
> Attachment: proof of concept working
--