MinWang edited comment on FLINK-15693 at 7/2/20, 1:05 PM:
----------------------------------------------------------
I suppressed the handleRpcInvocation and ran the tests. It’s all passed. It
seems no messages out during shutting down. I will keep digging.
was (Author: anglenet):
I suppressed the handleRpcInvocation and ran the tests. It’s all passed. It
seems no messages out. I will keep digging.
> Stop receiving incoming RPC messages when RpcEndpoint is closing
> ----------------------------------------------------------------
>
> Key: FLINK-15693
> URL: https://issues.apache.org/jira/browse/FLINK-15693
> Project: Flink
> Issue Type: Improvement
> Components: Runtime / Coordination
> Affects Versions: 1.9.1, 1.10.0
> Reporter: Till Rohrmann
> Priority: Major
> Fix For: 1.11.0
>
>
> When calling {{RpcEndpoint#closeAsync()}}, the system triggers
> {{RpcEndpoint#onStop}} and transitions the endpoint into the
> {{TerminatingState}}. In order to allow asynchronous clean up operations, the
> main thread executor is not shut down immediately. As a side effect, the
> {{RpcEndpoint}} still accepts incoming RPC messages from other components.
> I think it would be cleaner to no longer accept incoming RPC messages once we
> are in the {{TerminatingState}}. That way we would not worry about the
> internal state of the {{RpcEndpoint}} when processing RPC messages (similar
> to
> [here|https://github.com/apache/flink/blob/master/flink-runtime/src/main/java/org/apache/flink/runtime/taskexecutor/TaskExecutor.java#L952]).
--
This message was sent by Atlassian Jira