https://issues.apache.org/jira/browse/FLINK-18742?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Kostas Kloudas closed FLINK-18742.
----------------------------------
Fix Version/s: 1.11.2
1.12.0
Resolution: Fixed
Merged on master with 3394da15943a932e2a89cd40e6a6464c98765a29
and on release-1.11 with dad18a52a1a960efc7be3139abbbf9cae5b6d99f
> Some configuration args do not take effect at client
> ----------------------------------------------------
>
> Key: FLINK-18742
> URL: https://issues.apache.org/jira/browse/FLINK-18742
> Project: Flink
> Issue Type: Improvement
> Components: Command Line Client
> Affects Versions: 1.11.1
> Reporter: Matt Wang
> Assignee: Matt Wang
> Priority: Major
> Labels: pull-request-available
> Fix For: 1.12.0, 1.11.2
>
>
> Some configuration args from command line will not work at client, for
> example, the job sets the {color:#505f79}_classloader.resolve-order_{color}
> to _{color:#505f79}parent-first,{color}_ it can work at TaskManager, but
> Client doesn't.
> The *FlinkUserCodeClassLoaders* will be created before calling the method of
> _{color:#505f79}getEffectiveConfiguration(){color}_ at
> {color:#505f79}org.apache.flink.client.cli.CliFrontend{color}, so the
> _{color:#505f79}Configuration{color}_ used by
> _{color:#505f79}PackagedProgram{color}_ does not include Configuration args.
--
This message was sent by Atlassian Jira