https://issues.apache.org/jira/browse/FLINK-18742?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Kostas Kloudas closed FLINK-18742.
----------------------------------
    Fix Version/s: 1.11.2
                   1.12.0
       Resolution: Fixed

Merged on master with 3394da15943a932e2a89cd40e6a6464c98765a29
and on release-1.11 with dad18a52a1a960efc7be3139abbbf9cae5b6d99f

> Some configuration args do not take effect at client
> ----------------------------------------------------
>
>                 Key: FLINK-18742
>                 URL: https://issues.apache.org/jira/browse/FLINK-18742
>             Project: Flink
>          Issue Type: Improvement
>          Components: Command Line Client
>    Affects Versions: 1.11.1
>            Reporter: Matt Wang
>            Assignee: Matt Wang
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.12.0, 1.11.2
>
>
> Some configuration args from command line will not work at client, for 
> example, the job sets the {color:#505f79}_classloader.resolve-order_{color} 
> to _{color:#505f79}parent-first,{color}_ it can work at TaskManager, but 
> Client doesn't.
> The *FlinkUserCodeClassLoaders* will be created before calling the method of 
> _{color:#505f79}getEffectiveConfiguration(){color}_ at 
> {color:#505f79}org.apache.flink.client.cli.CliFrontend{color}, so the 
> _{color:#505f79}Configuration{color}_ used by 
> _{color:#505f79}PackagedProgram{color}_ does not include Configuration args.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to