https://issues.apache.org/jira/browse/FLINK-19226?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

ASF GitHub Bot updated FLINK-19226:
-----------------------------------
    Labels: pull-request-available  (was: )

> [Kinesis] [EFO] Connector reaches default max attempts for describeStream and 
> describeStreamConsumer when parallelism is high
> -----------------------------------------------------------------------------------------------------------------------------
>
>                 Key: FLINK-19226
>                 URL: https://issues.apache.org/jira/browse/FLINK-19226
>             Project: Flink
>          Issue Type: Improvement
>          Components: Connectors / Kinesis
>            Reporter: Hong Liang Teoh
>            Priority: Minor
>              Labels: pull-request-available
>             Fix For: 1.12.0
>
>
> *Background*
> When lazily registering the stream consumer on apps with high parallelism, 
> EFO connector hits default maximum number of attempts when calling 
> describeStream and describeStreamConsumer on the Kinesis Streams API.
> The default FullJitterBackoff constants are tuned to prevent this when 
> parallelism of 1024 is used.
> *Scope*
>  * See 
> [FLIP|https://cwiki.apache.org/confluence/display/FLINK/FLIP-128%3A+Enhanced+Fan+Out+for+AWS+Kinesis+Consumers]
>  for full list of configuration options
>  * Suggested changes:
> |flink.stream.describe.maxretries|50|
> |flink.stream.describe.backoff.base|2000L|
> |flink.stream.describe.backoff.max|5000L|
> |flink.stream.describestreamconsumer.maxretries|50|
> |flink.stream.describestreamconsumer.backoff.base|2000L|
> |flink.stream.describestreamconsumer.backoff.max|5000L|



--
This message was sent by Atlassian Jira