https://issues.apache.org/jira/browse/FLINK-20233?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17237904#comment-17237904
]
Jingsong Lee commented on FLINK-20233:
--------------------------------------
According to
[https://docs.oracle.com/javase/6/docs/platform/serialization/spec/version.html#6678]
, adding a field and its default value is good, is OK for compatibility, I'll
close this ticket.
> DataGeneratorSource should increment serialVersionUID
> -----------------------------------------------------
>
> Key: FLINK-20233
> URL: https://issues.apache.org/jira/browse/FLINK-20233
> Project: Flink
> Issue Type: Bug
> Components: Table SQL / Runtime
> Reporter: Jingsong Lee
> Assignee: Junning Liang
> Priority: Critical
> Labels: pull-request-available
> Fix For: 1.12.0
>
>
> In FLINK-18735 , enhanced DataGeneratorSource, the modification looks like
> incompatible.
> We should change serialVersionUID.
--
This message was sent by Atlassian Jira
(v8.3.4#803005)