https://issues.apache.org/jira/browse/FLINK-20717?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Piotr Nowojski updated FLINK-20717:
-----------------------------------
Release Note: Previously `idleTimeMsPerSecond` was defined as the time task
spent waiting for either the input or the back pressure. Now
idleTimeMsPerSecond` excludes back pressured time, so if the task is back
pressured it is not idle. The back pressured time is now measured separately as
`backPressuredTimeMsPerSecond`.
> Create backPressuredTimeMsPerSecond metric
> ------------------------------------------
>
> Key: FLINK-20717
> URL: https://issues.apache.org/jira/browse/FLINK-20717
> Project: Flink
> Issue Type: Sub-task
> Components: Runtime / Metrics, Runtime / Task
> Reporter: Piotr Nowojski
> Assignee: Piotr Nowojski
> Priority: Major
> Fix For: 1.13.0
>
>
> Create {{backPressuredTimeMsPerSecond}} metric, measured similarly to the
> existing {{idleTimeMsPerSecond}}.
--
This message was sent by Atlassian Jira
(v8.3.4#803005)