Robert Metzger commented on FLINK-10276:
----------------------------------------

Maybe adding a config option that allows overwriting existing configuration 
options on TaskManagers would solve the issue?
Something like "taskmanager.configuration.taskmanager-overwrites-file"
This way, all resource manager implementations would benefit from this feature.

For some resource managers, we would need to figure out how to send the 
additional config file to the TaskManagers (not sure if the "ship files" 
feature in YARN is sufficient, from a user experience perspective)

> Job Manager and Task Manager Metrics Reporter Ports Configuration
> -----------------------------------------------------------------
>
>                 Key: FLINK-10276
>                 URL: https://issues.apache.org/jira/browse/FLINK-10276
>             Project: Flink
>          Issue Type: New Feature
>          Components: Runtime / Configuration, Runtime / Metrics
>            Reporter: Deirdre Kong
>            Priority: Major
>
> *Problem Statement:*
> When deploying Flink using YARN, the job manager and task manager can be on 
> the same node or different nodes.  Say I specify the port range to be 
> 9249-9250, if JM and TM are deployed on the same node, the port for JM will 
> be 9249 and the port for TM will be 9250.  If JM and TM are deployed on 
> different nodes, then the ports for JM and TM will be 9249.
> I can only configure Prometheus once for the ports to scrape JM and TMs 
> metrics.  In this case, I won't know whether port 9249 is for JM or TM.  If 
> would be great if we can specify in flink-conf.yaml on the port we want for 
> JM reporter and TMs reporter.
> *Comment from Till:*
> I think we could extend Vino's proposal for Yarn as well: Maybe it makes 
> sense to allow to override certain configuration settings for the 
> TaskManagers when deploying on Yarn. That way one could define a fixed port 
> for the JM and a port range for the TMs. Having such a distinction you can 
> configure your Prometheus to scrape for the single JM and the TMs 
> individually. However, Flink does not yet support such a feature. You can 
> open a JIRA issue to track the problem.
>  



--
This message was sent by Atlassian Jira