Jeffrey Charles commented on FLINK-21350:
-----------------------------------------
I'm also happy to work on a PR to fix the bug. I think the changes should be
limited to the RowConverter and adding a test case in ParquetRowInputFormatTest.
> ParquetInputFormat incorrectly interprets timestamps encoded in microseconds
> as timestamps encoded in milliseconds
> ------------------------------------------------------------------------------------------------------------------
>
> Key: FLINK-21350
> URL: https://issues.apache.org/jira/browse/FLINK-21350
> Project: Flink
> Issue Type: Bug
> Components: Formats (JSON, Avro, Parquet, ORC, SequenceFile)
> Affects Versions: 1.12.0, 1.12.1
> Reporter: Jeffrey Charles
> Priority: Major
>
> Given a parquet file with a schema that has a field with a physical type of
> INT64 and a logical type of TIMESTAMP_MICROS, all of the ParquetInputFormat
> sub-classes deserialize the timestamp as tens of thousands of years in the
> future.
> Looking at the code in
> [https://github.com/apache/flink/blob/release-1.12.1/flink-formats/flink-parquet/src/main/java/org/apache/flink/formats/parquet/utils/RowConverter.java#L326,]
> it looks to me like the row converter is interpreting the field value as if
> it contained milliseconds and not microseconds. Specifically both millisecond
> and microsecond processing share the same code path to instantiate a
> java.sql.timestamp which takes a millisecond value in its constructor and the
> microsecond case statement is passing it a value in microseconds. I tested a
> change locally where I divide the value by 1000 in the microseconds case
> statement and that results in a timestamp with the expected value.
--