Aljoscha Krettek commented on FLINK-3669:
-----------------------------------------
Hi,
I'll be looking at your code today.
For the tests, the idea is to put tests that verify the interplay of the
complete system into an *ITCase and smaller, self-contained tests into a *Test.
Normally ITCases also take a lot longer to execute.
> WindowOperator registers a lot of timers at StreamTask
> ------------------------------------------------------
>
> Key: FLINK-3669
> URL: https://issues.apache.org/jira/browse/FLINK-3669
> Project: Flink
> Issue Type: Bug
> Components: Streaming
> Affects Versions: 1.0.1
> Reporter: Aljoscha Krettek
> Assignee: Konstantin Knauf
> Priority: Blocker
>
> Right now, the WindowOperator registers a timer at the StreamTask for every
> processing-time timer that a Trigger registers. We should combine several
> registered trigger timers to only register one low-level timer (timer
> coalescing).
--
This message was sent by Atlassian JIRA