https://issues.apache.org/jira/browse/FLINK-20443?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17411704#comment-17411704
]
Yun Gao commented on FLINK-20443:
---------------------------------
Hi [~liliwei], very thanks for opening the PR!
There should be once a discussion regarding how to deal with processing time at
the end of stream, might be related to
[https://cwiki.apache.org/confluence/display/FLINK/FLIP-134%3A+Batch+execution+for+the+DataStream+API],
I'll also have a check of the current status.
> ContinuousProcessingTimeTrigger doesn't fire at the end of the window
> ---------------------------------------------------------------------
>
> Key: FLINK-20443
> URL: https://issues.apache.org/jira/browse/FLINK-20443
> Project: Flink
> Issue Type: Improvement
> Components: API / DataStream
> Reporter: Gee
> Priority: Not a Priority
> Labels: pull-request-available
>
>
> {code:java}
> srcStream
> .timeWindowAll(Time.seconds(60))
> .trigger(ContinuousProcessingTimeTrigger.of(Time.seconds(10)))...
> {code}
>
> This can correctly calculate the following interval result : 0-10s 10-20s
> 20-30s 30-40s 40-50s
> But this lost data which was send in 50-60s.
> Because when the first window ends, the time is 59.9999s, it is not equal to
> window-end-time(60s).So it will not enter the if judgment.
--
This message was sent by Atlassian Jira
(v8.3.4#803005)