https://issues.apache.org/jira/browse/FLINK-18996?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Timo Walther updated FLINK-18996:
---------------------------------
Priority: Critical (was: Minor)
> Avoid disorder for time interval join
> -------------------------------------
>
> Key: FLINK-18996
> URL: https://issues.apache.org/jira/browse/FLINK-18996
> Project: Flink
> Issue Type: Improvement
> Components: Table SQL / Runtime
> Reporter: Benchao Li
> Priority: Critical
> Labels: auto-deprioritized-major
>
> Currently, the time interval join will produce data with rowtime later than
> watermark. If we use the rowtime again in downstream, e.t. window
> aggregation, we'll lose some data.
>
> reported from user-zh:
> [http://apache-flink.147419.n8.nabble.com/Re-flink-interval-join-tc4458.html#none]
--
This message was sent by Atlassian Jira
(v8.3.4#803005)