https://issues.apache.org/jira/browse/FLINK-20443?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Arvid Heise resolved FLINK-20443.
---------------------------------
Fix Version/s: 1.13.4
1.14.1
Resolution: Fixed
> ContinuousProcessingTimeTrigger doesn't fire at the end of the window
> ---------------------------------------------------------------------
>
> Key: FLINK-20443
> URL: https://issues.apache.org/jira/browse/FLINK-20443
> Project: Flink
> Issue Type: Improvement
> Components: API / DataStream
> Reporter: Gee
> Assignee: liwei li
> Priority: Major
> Labels: pull-request-available
> Fix For: 1.15.0, 1.14.1, 1.13.4
>
>
>
> {code:java}
> srcStream
> .timeWindowAll(Time.seconds(60))
> .trigger(ContinuousProcessingTimeTrigger.of(Time.seconds(10)))...
> {code}
>
> This can correctly calculate the following interval result : 0-10s 10-20s
> 20-30s 30-40s 40-50s
> But this lost data which was send in 50-60s.
> Because when the first window ends, the time is 59.9999s, it is not equal to
> window-end-time(60s).So it will not enter the if judgment.
--