https://issues.apache.org/jira/browse/FLINK-22108?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Flink Jira Bot updated FLINK-22108:
-----------------------------------
      Labels: auto-deprioritized-major auto-deprioritized-minor  (was: 
auto-deprioritized-major stale-minor)
    Priority: Not a Priority  (was: Minor)

This issue was labeled "stale-minor" 7 days ago and has not received any 
updates so it is being deprioritized. If this ticket is actually Minor, please 
raise the priority and ask a committer to assign you the issue or revive the 
public discussion.


> Ephemeral socket address was checkpointed to state and restored back in 
> CollectSinkOperatorCoordinator
> ------------------------------------------------------------------------------------------------------
>
>                 Key: FLINK-22108
>                 URL: https://issues.apache.org/jira/browse/FLINK-22108
>             Project: Flink
>          Issue Type: Bug
>          Components: API / DataStream
>    Affects Versions: 1.13.0
>            Reporter: Kezhu Wang
>            Priority: Not a Priority
>              Labels: auto-deprioritized-major, auto-deprioritized-minor
>
> {{CollectSinkOperatorCoordinator}} checkpointed its {{address}} field to 
> state and restored back. That field is listener address of 
> {{CollectSinkFunction}}. After {{resetToCheckpoint}} (eg. global failover}}, 
> {{address}} is meaningless. If client request comes before 
> {{CollectSinkAddressEvent}}, it will use that meaningless address for 
> connection. In best situation, error happens, and nothing hurts. In bad 
> situation, no one knows where the restored address points to now. 
> cc  [~TsReaper] [~ykt836]



--
This message was sent by Atlassian Jira
(v8.20.1#820001)

Reply via email to