https://issues.apache.org/jira/browse/FLINK-26759?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17510379#comment-17510379
]
Martijn Visser commented on FLINK-26759:
----------------------------------------
If there's no desire to change old code or if they are afraid to introduce
instability, they should keep running their existing version. But that does
mean that they will miss out on new features, bug fixes, new improvements or
even lack of support. That's the trade off the user of Flink needs to make.
> Legacy source support waiting for recordWriter to be available
> --------------------------------------------------------------
>
> Key: FLINK-26759
> URL: https://issues.apache.org/jira/browse/FLINK-26759
> Project: Flink
> Issue Type: Improvement
> Components: Connectors / Common, Runtime / Checkpointing
> Affects Versions: 1.13.0, 1.14.0, 1.15.0
> Reporter: fanrui
> Priority: Major
>
> In order for Unaligned Checkpoint not to be blocked, StreamTask#processInput
> will check recordWriter.isAvailable(). If not available, the data will not be
> processed until recordWriter is available.
> The new Source api is compatible with the above logic, but Legacy Source is
> not compatible with the above logic. When using Unaligned Checkpoint, if the
> backpressure of Legacy Source is high, the Checkpoint duration of Legacy
> Source will be very long.
>
> Since legacy sources are often used in production, can we add logic to wait
> for recordWriter to be available for legacy source?
--
This message was sent by Atlassian Jira
(v8.20.1#820001)