xintongsong commented on code in PR #20042:
URL: https://github.com/apache/flink/pull/20042#discussion_r903476652


##########
flink-clients/src/main/java/org/apache/flink/client/cli/CliFrontend.java:
##########
@@ -208,6 +210,16 @@ protected void runApplication(String[] args) throws 
Exception {
                             Collections.singletonList(uri.toString()));
         }
 
+        // In HA mode, we only support single-execute jobs at the moment. 
Here, we manually
+        // generate the job id, if not configured, to keep it consistent 
across failover.
+        if 
(HighAvailabilityMode.isHighAvailabilityModeActivated(effectiveConfiguration)
+                && !effectiveConfiguration
+                        
.getOptional(PipelineOptionsInternal.PIPELINE_FIXED_JOB_ID)
+                        .isPresent()) {
+            effectiveConfiguration.set(
+                    PipelineOptionsInternal.PIPELINE_FIXED_JOB_ID, new 
JobID().toHexString());
+        }
+

Review Comment:
   I'm not sure `CliFrontend` is the best place to set this job id. It's not 
the only entry point that an application can be deployed. AFAIK, Flink 
Kubernetes Operator uses `ApplicationDeployer` directly. Maybe we should move 
this logic to `ApplicationDeployer`.



-- 