https://issues.apache.org/jira/browse/FLINK-28318?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

yutao closed FLINK-28318.
-------------------------
    Resolution: Cannot Reproduce

> table idle  state ttl configure does not have check when window  size bigger 
> than table state ttl
> -------------------------------------------------------------------------------------------------
>
>                 Key: FLINK-28318
>                 URL: https://issues.apache.org/jira/browse/FLINK-28318
>             Project: Flink
>          Issue Type: Improvement
>          Components: Table SQL / Planner, Table SQL / Runtime
>    Affects Versions: 1.12.4, 1.13.5, 1.14.4
>         Environment: flinksql 1.12.4
>            Reporter: yutao
>            Priority: Major
>
> example: my tumbling window size is 1 day ,but  i config  
> table.exec.state.ttl is 1 hour, if count(1) group by somthing  and  some key 
> more than a hour comming element ,we can get a error vlaue.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to