Matyas Orhidi created FLINK-31717:
-------------------------------------
Summary: Unit tests running with local kube config
Key: FLINK-31717
URL: https://issues.apache.org/jira/browse/FLINK-31717
Project: Flink
Issue Type: New Feature
Components: Kubernetes Operator
Reporter: Matyas Orhidi
Some unit tests are using local kube environment. This can be dangerous when
pointing to sensitive clusters e.g. in prod.
{{2023-04-03 12:32:53,956 i.f.k.c.Config [DEBUG] Found for
Kubernetes config at: [/Users/<redacted>/.kube/config].
}}
A misconfigured kube config environment revealed the issue:
{{[ERROR] Tests run: 2, Failures: 0, Errors: 2, Skipped: 0, Time elapsed: 0.012
s <<< FAILURE! - in org.apache.flink.kubernetes.operator.FlinkOperatorTest
[ERROR]
org.apache.flink.kubernetes.operator.FlinkOperatorTest.testConfigurationPassedToJOSDK
Time elapsed: 0.008 s <<< ERROR!
java.lang.NullPointerException
at
org.apache.flink.kubernetes.operator.FlinkOperatorTest.testConfigurationPassedToJOSDK(FlinkOperatorTest.java:63)
[ERROR]
org.apache.flink.kubernetes.operator.FlinkOperatorTest.testLeaderElectionConfig
Time elapsed: 0.004 s <<< ERROR!
java.lang.NullPointerException
at
org.apache.flink.kubernetes.operator.FlinkOperatorTest.testLeaderElectionConfig(FlinkOperatorTest.java:108)
}}
move ~/.kube/config
--