https://issues.apache.org/jira/browse/FLINK-32191?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Yangze Guo closed FLINK-32191.
------------------------------
    Fix Version/s: 1.18.0
       Resolution: Fixed

> Support for configuring tcp keepalive related parameters.
> ---------------------------------------------------------
>
>                 Key: FLINK-32191
>                 URL: https://issues.apache.org/jira/browse/FLINK-32191
>             Project: Flink
>          Issue Type: Improvement
>          Components: Runtime / Network
>            Reporter: dizhou cao
>            Assignee: Weihua Hu
>            Priority: Minor
>              Labels: pull-request-available
>             Fix For: 1.18.0
>
>
> We encountered a case in our production environment where the netty client 
> was unable to send data to the server due to an abnormality in the switch 
> link. However, client can only detect the abnormality after RTO timeout 
> retransmission failure, which takes about 15 minutes in our production 
> environment. This may result in a 15-minute job unavailability. We hope to 
> perform failover and reschedule job more quickly. Flink has already enabled 
> keepalive, but the default keepalive idle time is 2 hours. We can adjust the 
> timeout of TCP keepalive by configuring TCP_KEEPIDLE, TCP_KEEPINTERVAL, and 
> TCP_KEEPCOUNT. These configurations are already supported at the Netty.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to