https://issues.apache.org/jira/browse/FLINK-34076?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Khanh Vu updated FLINK-34076:
-----------------------------
    Description: 
The 
[commit|https://github.com/apache/flink-connector-aws/commit/01f112bd5a69f95cd5d2a4bc7e08d1ba9a81d56a]
 which stops bundling `flink-connector-base` with `flink-connector-kinesis` has 
caused kinesis sink failing to create when using Table API as required classes 
from `flink-connector-base` are not loaded in execution.

E.g. with following depenency only in pom.xml
{code:java}
        <dependency>
            <groupId>org.apache.flink</groupId>
            <artifactId>flink-connector-kinesis</artifactId>
            <version>${flink.connector.kinesis.version}</version>
        </dependency>
{code}

following exception will be thrown:
{code:java}
Caused by: org.apache.flink.table.api.ValidationException: Connector 'kinesis' 
can only be used as a source. It cannot be used as a sink.
at 
org.apache.flink.table.factories.FactoryUtil.enrichNoMatchingConnectorError(FactoryUtil.java:756)
at 
org.apache.flink.table.factories.FactoryUtil.discoverTableFactory(FactoryUtil.java:710)
at 
org.apache.flink.table.factories.FactoryUtil.createDynamicTableSink(FactoryUtil.java:265)
{code}

The fix is to explicitly specify `flink-connector-base` as dependency of the 
project:

{code:java}
                <dependency>
                        <groupId>org.apache.flink</groupId>
                        <artifactId>flink-connector-kinesis</artifactId>
                        <version>${flink.connector.kinesis.version}</version>
                </dependency>
                <dependency>
                        <groupId>org.apache.flink</groupId>
                        <artifactId>flink-connector-base</artifactId>
                        <version>${flink.version}</version>
                        <scope>provided</scope>
                </dependency>
{code}

In general, `flink-connector-base` should be pulled in by default when pulling 
in the connector, the current separation adds unnecessary hassle to use the 
connector.

  was:
The 
[commit|https://github.com/apache/flink-connector-aws/commit/01f112bd5a69f95cd5d2a4bc7e08d1ba9a81d56a]
 which stops bundling `flink-connector-base` with `flink-connector-kinesis` has 
caused kinesis sink failing to create when using Table API as required classes 
from `flink-connector-base` are not loaded in execution.

{{E.g. with following depenency only in pom.xml}}
{{```}}
{{{{Caused by: org.apache.flink.table.api.ValidationException: Connector 
'kinesis' can only be used as a source. It cannot be used as a sink.}}
{{at 
org.apache.flink.table.factories.FactoryUtil.enrichNoMatchingConnectorError(FactoryUtil.java:756)}}
{{at 
org.apache.flink.table.factories.FactoryUtil.discoverTableFactory(FactoryUtil.java:710)}}
{{at 
org.apache.flink.table.factories.FactoryUtil.createDynamicTableSink(FactoryUtil.java:265)}}
{{... 20 more}}}}
{{```}}

following exception will be thrown:
```
{{Caused by: org.apache.flink.table.api.ValidationException: Connector 
'kinesis' can only be used as a source. It cannot be used as a sink.
at 
org.apache.flink.table.factories.FactoryUtil.enrichNoMatchingConnectorError(FactoryUtil.java:756)
at 
org.apache.flink.table.factories.FactoryUtil.discoverTableFactory(FactoryUtil.java:710)
at 
org.apache.flink.table.factories.FactoryUtil.createDynamicTableSink(FactoryUtil.java:265)
... 20 more}}
```

Workaround is to explicitly specify `flink-connector-base` as dependency of the 
project:

```
{{<dependency>
<groupId>org.apache.flink</groupId>
<artifactId>flink-connector-kinesis</artifactId>
<version>${flink.connector.kinesis.version}</version>
</dependency>
<dependency>
<groupId>org.apache.flink</groupId>
<artifactId>flink-connector-base</artifactId>
<version>${flink.version}</version>
<scope>provided</scope>
</dependency>}}
```

In general, `flink-connector-base` should be pulled in by default when pulling 
in the connector, the current separation adds unnecessary hassle to use the 
connector.


> flink-connector-base missing fails kinesis table sink to create
> ---------------------------------------------------------------
>
>                 Key: FLINK-34076
>                 URL: https://issues.apache.org/jira/browse/FLINK-34076
>             Project: Flink
>          Issue Type: Bug
>          Components: Connectors / Kinesis
>    Affects Versions: aws-connector-4.2.0
>            Reporter: Khanh Vu
>            Priority: Major
>
> The 
> [commit|https://github.com/apache/flink-connector-aws/commit/01f112bd5a69f95cd5d2a4bc7e08d1ba9a81d56a]
>  which stops bundling `flink-connector-base` with `flink-connector-kinesis` 
> has caused kinesis sink failing to create when using Table API as required 
> classes from `flink-connector-base` are not loaded in execution.
> E.g. with following depenency only in pom.xml
> {code:java}
>         <dependency>
>             <groupId>org.apache.flink</groupId>
>             <artifactId>flink-connector-kinesis</artifactId>
>             <version>${flink.connector.kinesis.version}</version>
>         </dependency>
> {code}
> following exception will be thrown:
> {code:java}
> Caused by: org.apache.flink.table.api.ValidationException: Connector 
> 'kinesis' can only be used as a source. It cannot be used as a sink.
> at 
> org.apache.flink.table.factories.FactoryUtil.enrichNoMatchingConnectorError(FactoryUtil.java:756)
> at 
> org.apache.flink.table.factories.FactoryUtil.discoverTableFactory(FactoryUtil.java:710)
> at 
> org.apache.flink.table.factories.FactoryUtil.createDynamicTableSink(FactoryUtil.java:265)
> {code}
> The fix is to explicitly specify `flink-connector-base` as dependency of the 
> project:
> {code:java}
>               <dependency>
>                       <groupId>org.apache.flink</groupId>
>                       <artifactId>flink-connector-kinesis</artifactId>
>                       <version>${flink.connector.kinesis.version}</version>
>               </dependency>
>               <dependency>
>                       <groupId>org.apache.flink</groupId>
>                       <artifactId>flink-connector-base</artifactId>
>                       <version>${flink.version}</version>
>                       <scope>provided</scope>
>               </dependency>
> {code}
> In general, `flink-connector-base` should be pulled in by default when 
> pulling in the connector, the current separation adds unnecessary hassle to 
> use the connector.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to