Gyula Fora created FLINK-34266:
----------------------------------
Summary: Output ratios should be computed over the whole metric
window instead of averaged
Key: FLINK-34266
URL: https://issues.apache.org/jira/browse/FLINK-34266
Project: Flink
Issue Type: Improvement
Components: Autoscaler
Reporter: Gyula Fora
Currently Output ratios are computed during metric collection based on the
current in/out metrics an stored as part of the collected metrics.
During evaluation the output ratios previously computed are then averaged
together in the metric window. This however leads to incorrect computation due
to the nature of the computation and averaging.
Example:
Let's look at a window operator that simply sorts and re-emits events in
windows. During the window collection phase, output ratio will be computed and
stored as 0. During the window computation the output ratio will be
last_input_rate / window_size. Depending on the last input rate observation
this can be off when averaged into any direction.
--
This message was sent by Atlassian Jira