Liu Liu created FLINK-35764:
-------------------------------
Summary: TimerGauge is incorrect when update is called during a
measurement
Key: FLINK-35764
URL: https://issues.apache.org/jira/browse/FLINK-35764
Project: Flink
Issue Type: Bug
Components: Runtime / Metrics
Affects Versions: 1.19.0, 1.18.0, 1.17.0, 1.16.0, 1.15.0
Reporter: Liu Liu
Currently in {{{}TimerGauge{}}}, the {{currentMeasurement}} in {{markEnd}} is
incorrectly set to the time since the last {{{}markStart{}}}. When calling
{{{}markStart -> update -> markEnd{}}}, this will result in the time between
{{markStart}} and {{update}} being counted twice. A piece of test code that
reflects this scenario:
{code:java}
@Test
void testUpdateBeforeMarkingEnd() {
ManualClock clock = new ManualClock(42_000_000);
// time span = 2 intervals
TimerGauge gauge = new TimerGauge(clock, 2 * View.UPDATE_INTERVAL_SECONDS);
// the event spans 2 intervals
// interval 1
gauge.markStart();
clock.advanceTime(SLEEP, TimeUnit.MILLISECONDS);
gauge.update();
// interval 2
clock.advanceTime(SLEEP, TimeUnit.MILLISECONDS);
gauge.markEnd();
gauge.update();
// expected: 2, actual: 3
assertThat(gauge.getValue()).isEqualTo(SLEEP /
View.UPDATE_INTERVAL_SECONDS);
}
{code}
Proposed changes:
# Modify {{markEnd}} so that updates to {{currentCount}} and
{{accumulatedCount}} resembles those in {{{}update{}}}.
# Add the test case to {{{}TimeGaugeTest{}}}.
--