davidradl commented on code in PR #25815:
URL: https://github.com/apache/flink/pull/25815#discussion_r1894022766
##########
flink-runtime/src/test/java/org/apache/flink/streaming/util/KeyedTwoInputStreamOperatorTestHarness.java:
##########
@@ -64,8 +67,24 @@ public KeyedTwoInputStreamOperatorTestHarness(
}
public int numKeyedStateEntries() {
- AbstractStreamOperator<?> abstractStreamOperator =
(AbstractStreamOperator<?>) operator;
- KeyedStateBackend<Object> keyedStateBackend =
abstractStreamOperator.getKeyedStateBackend();
+ KeyedStateBackend<?> keyedStateBackend;
+ if (operator instanceof AbstractAsyncStateStreamOperator) {
Review Comment:
as reflection is quite costly and the operator is an instance variable, can
we organize the code so the reflection is done once and caches rather than on
every access.
I suggest working out what type of operator we have in the constructor and
stash in an instance variable; maybe using an enum for the types of operators .
Or if we think that the types of operator are known and stable, then we could
have the enum operatorType in the `AbstractStreamOperator` class, and set the
appropriate value as each child is constructed; avoiding the instanceof
completely.
With method could then be a switch on the enum
--