sn-12-3 commented on code in PR #25528:
URL: https://github.com/apache/flink/pull/25528#discussion_r1921107801
##########
flink-python/pyflink/table/tests/test_table_environment_api.py:
##########
@@ -443,6 +443,23 @@ def test_to_data_stream_local_time(self):
'+I[2, 1970-06-07, 08:09:10, 1970-06-07T08:09:10]']
self.assertEqual(expected, results)
+ def test_to_data_stream(self):
+ self.env.set_parallelism(1)
+ t_env = StreamTableEnvironment.create(
+ self.env,
+ environment_settings=EnvironmentSettings.in_streaming_mode())
+ table = t_env.from_elements([(1, "Hi", "Hello"), (2, "Hello", "Hi")],
["a", "b", "c"])
+ new_table = table.select(table.a + 1, table.b + 'flink', table.c)
+ ds = t_env.to_data_stream(table=new_table,
type_info=Types.ROW([Types.LONG(),
+
Types.STRING(),
+
Types.STRING()]))
+ test_sink = DataStreamTestSinkFunction()
+ ds.add_sink(test_sink)
+ self.env.execute("test_to_data_stream")
Review Comment:
I'm afraid I understand, this is adding the `sink` operator to the
`dataStream` function, there is no functions related to `delete` or `update`.
After the changes based on the review comments, this is outdated as no new
test has been added in this file. Only `toAppendStream` relevant test case has
been removed.
--