MartijnVisser commented on code in PR #29307: URL: https://github.com/apache/flink/pull/29307#discussion_r4122252925
########## flink-table/flink-table-planner/src/test/java/org/apache/flink/table/planner/plan/nodes/exec/testutils/CommonSemanticTestBase.java: ########## @@ -58,9 +60,21 @@ * whether the execution result is semantically correct. */ @ExtendWith(MiniClusterExtension.class) +@Execution(ExecutionMode.CONCURRENT) Review Comment: On master these never run concurrently: the root pom defaults classes and methods to `same_thread`, and surefire forks are separate JVMs. So concurrency can't be what breaks FLINK-40670. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]