twalthr commented on code in PR #29419:
URL: https://github.com/apache/flink/pull/29419#discussion_r4220456132
##########
flink-table/flink-table-planner/src/main/java/org/apache/flink/table/planner/plan/nodes/physical/stream/StreamPhysicalProcessTableFunction.java:
##########
@@ -371,6 +371,46 @@ private static void verifyInputSize(TableConfig
tableConfig, int providedInputAr
// Shared utilities
//
--------------------------------------------------------------------------------------------
+ /**
+ * Derives per-input {@link InputProperty}s. Broadcast table arguments
require a broadcast
+ * distribution, all other inputs use the default.
+ */
+ private List<InputProperty> deriveInputProperties(RexCall call) {
+ final boolean[] broadcastByInput = broadcastByInput(call,
getInputs().size());
+ return IntStream.range(0, getInputs().size())
+ .mapToObj(
+ i ->
+ broadcastByInput[i]
+ ? InputProperty.builder()
+ .requiredDistribution(
+
InputProperty.BROADCAST_DISTRIBUTION)
+ .build()
+ : InputProperty.DEFAULT)
+ .collect(Collectors.toList());
+ }
+
+ /** Returns whether the given signature declares a table argument with
broadcast semantics. */
+ public static boolean hasBroadcastTables(List<StaticArgument> staticArgs) {
+ return staticArgs.stream()
+ .anyMatch(arg ->
arg.is(StaticArgumentTrait.BROADCAST_SEMANTIC_TABLE));
+ }
+
+ /**
+ * Returns a flag per input indicating whether it is a table argument with
broadcast semantics.
+ */
+ public static boolean[] broadcastByInput(RexCall call, int inputCount) {
Review Comment:
I feel this is a micro optimization with little impact. Given that we limit
inputs to 20. Boolean is easier for debugging.
--