Biasqo commented on PR #171:
URL: 
https://github.com/apache/flink-connector-jdbc/pull/171#issuecomment-6602080709

   @MartijnVisser thanks for the review
   
   About the timestamps (replied above) - it's a known ClickHouse JDBC V2 bug. 
Binding as strings didn't work, so forcing -Duser.timezone=UTC is the only 
workaround i found to fix the 15 failing ITCases
   About the keys - ClickHouse automatically creates the PRIMARY KEY from ORDER 
BY fields. You must use these same fields as pkField in Flink to avoid `Cannot 
UPDATE key column`. The PK can be a subset of ORDER BY, but it must follow the 
exact same order.


-- 