https://issues.apache.org/jira/browse/FLINK-6311?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15974069#comment-15974069
 ] 

Tzu-Li (Gordon) Tai commented on FLINK-6311:
--------------------------------------------

the {{flink-connector-kinesis}} module is only included as a separate build 
profile ("include-kinesis"). We did this because of AWS License issues, and do 
not build the kinesis connector along with the other code. But this shouldn't 
be relevant for this JIRA, you can still proceed to fix it if you want to :)

> NPE in FlinkKinesisConsumer if source was closed before run
> -----------------------------------------------------------
>
>                 Key: FLINK-6311
>                 URL: https://issues.apache.org/jira/browse/FLINK-6311
>             Project: Flink
>          Issue Type: Bug
>          Components: Kinesis Connector
>            Reporter: Tzu-Li (Gordon) Tai
>            Assignee: mingleizhang
>
> This was reported by an user: 
> http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/Flink-errors-out-and-job-fails-IOException-from-CollectSink-open-td12606.html
> The {{shutdownFetcher}} method of {{KinesisDataFetcher}} is not protected 
> against the condition when the source was closed before it started running. 
> Both {{mainThread}} and {{shardConsumersExecutor}} should have null checks.



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to