https://issues.apache.org/jira/browse/GEODE-8683?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Nabarun Nag closed GEODE-8683.
------------------------------
> maximum-time-between-pings parameter in GatewayReceiver creation does not
> have any effect
> -----------------------------------------------------------------------------------------
>
> Key: GEODE-8683
> URL: https://issues.apache.org/jira/browse/GEODE-8683
> Project: Geode
> Issue Type: Bug
> Components: wan
> Reporter: Alberto Gomez
> Assignee: Alberto Gomez
> Priority: Major
> Labels: pull-request-available
> Fix For: 1.14.0
>
>
> The maximum-time-between-pings parameter than can be set at gateway receiver
> creation has no effect, i.e. the value used as maximum time between pings for
> gateway sender connections to the gateway receiver is either the default
> value (60000) or the one set on the server where the receiver is running.
> The reason is that the ClientHealthMonitor is a server-side singleton that
> monitors the health of all clients. The value set for this parameter in the
> ClientHealthMonitor is first set when the server is started and the first
> Acceptor is created.
--