https://issues.apache.org/jira/browse/HBASE-3327?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13081361#comment-13081361
]
Yi Liang commented on HBASE-3327:
---------------------------------
Is there a patch for 0.90.3?
> For increment workloads, retain memstores in memory after flushing them
> -----------------------------------------------------------------------
>
> Key: HBASE-3327
> URL: https://issues.apache.org/jira/browse/HBASE-3327
> Project: HBase
> Issue Type: Improvement
> Components: regionserver
> Reporter: Karthik Ranganathan
>
> This is an improvement based on our observation of what happens in an
> increment workload. The working set is typically small and is contained in
> the memstores.
> 1. The reason the memstores get flushed is because the number of wal logs
> limit gets hit.
> 2. This in turn triggers compactions, which evicts the block cache.
> 3. Flushing of memstore and eviction of the block cache causes disk reads for
> increments coming in after this because the data is no longer in memory.
> We could solve this elegantly by retaining the memstores AFTER they are
> flushed into files. This would mean we can quickly populate the new memstore
> with the working set of data from memory itself without having to hit disk.
> We can throttle the number of such memstores we retain, or the memory
> allocated to it. In fact, allocating a percentage of the block cache to this
> would give us a huge boost.
--
This message is automatically generated by JIRA.
For more information on JIRA, see: http://www.atlassian.com/software/jira