https://issues.apache.org/jira/browse/HBASE-15408?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15182529#comment-15182529
]
Phil Yang commented on HBASE-15408:
-----------------------------------
Can we catch the OutOfOrderScannerNextException and retry in
MetaTableAccessor.fullScan(Connection connection, QueryType type)(Line 235)?
> MiniCluster's master crash on initialization and unittest timeout
> -----------------------------------------------------------------
>
> Key: HBASE-15408
> URL: https://issues.apache.org/jira/browse/HBASE-15408
> Project: HBase
> Issue Type: Bug
> Reporter: Phil Yang
> Attachments: fail.txt
>
>
> These days there are many tests timeout on build.apache.org. I have no log on
> timeout tests but I find a possible reason: master crash on initialization
> and minicluster will log "No master found; retry" forever. The crash is
> caused by OutOfOrderScannerNextException.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)