https://issues.apache.org/jira/browse/HIVE-10591?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Prasanth Jayachandran updated HIVE-10591:
-----------------------------------------
    Attachment: HIVE-10591.3.patch

> Support limited integer type promotion in ORC
> ---------------------------------------------
>
>                 Key: HIVE-10591
>                 URL: https://issues.apache.org/jira/browse/HIVE-10591
>             Project: Hive
>          Issue Type: New Feature
>    Affects Versions: 1.3.0
>            Reporter: Prasanth Jayachandran
>            Assignee: Prasanth Jayachandran
>         Attachments: HIVE-10591.1.patch, HIVE-10591.2.patch, 
> HIVE-10591.2.patch, HIVE-10591.3.patch, HIVE-10591.3.patch, HIVE-10591.3.patch
>
>
> ORC currently does not support schema-on-read. If we alter an ORC table with 
> 'int' type to 'bigint' and if we query the altered table ClassCastException 
> will be thrown as the schema on read from table descriptor will expect 
> LongWritable whereas ORC will return IntWritable based on file schema stored 
> within ORC file. OrcSerde currently doesn't do any type conversions or type 
> promotions for performance reasons in inner loop. Since smallints, ints and 
> bigints are stored in the same way in ORC, it will be possible be allow such 
> type promotions without hurting performance. Following type promotions can be 
> supported without any casting
> smallint -> int
> smallint -> bigint
> int -> bigint
> Tinyint promotion is not possible without casting as tinyints are stored 
> using RLE byte writer whereas smallints, ints and bigints are stored using 
> RLE integer writer.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to