https://issues.apache.org/jira/browse/HIVE-23036?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Panagiotis Garefalakis reassigned HIVE-23036:
---------------------------------------------


> Incorrect ORC PPD eval with sub-millisecond timestamps
> ------------------------------------------------------
>
>                 Key: HIVE-23036
>                 URL: https://issues.apache.org/jira/browse/HIVE-23036
>             Project: Hive
>          Issue Type: Bug
>            Reporter: Panagiotis Garefalakis
>            Assignee: Panagiotis Garefalakis
>            Priority: Major
>
> See [ORC-611|https://issues.apache.org/jira/browse/ORC-611] for more details
> ORC stores timestamps with:
>  - nanosecond precision for the data itself
>  - milliseconds precision for min-max statistics
> As both min and max are rounded to the same value,  timestamps with ns 
> precision will not pass the PPD evaluator.
> {code:java}
> create table tsstat (ts timestamp) stored as orc;
> insert into tsstat values ("1970-01-01 00:00:00.0005");
> select * from tsstat where ts = "1970-01-01 00:00:00.0005";
> -- returned 0 rows{code}
> ORC PPD evaluation currently happens as part of OrcInputFormat 
> [https://github.com/apache/hive/blob/7e39a2c13711f9377c9ce1edb4224880421b1ea5/ql/src/java/org/apache/hadoop/hive/ql/io/orc/OrcInputFormat.java#L2314]



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to