https://issues.apache.org/jira/browse/IGNITE-1391?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Vladimir Ozerov closed IGNITE-1391.
-----------------------------------

> Platform .Net: Messaging.RemoteListen causes deadlock when remote node 
> interop is initializing
> ----------------------------------------------------------------------------------------------
>
>                 Key: IGNITE-1391
>                 URL: https://issues.apache.org/jira/browse/IGNITE-1391
>             Project: Ignite
>          Issue Type: Bug
>          Components: interop
>    Affects Versions: 1.1.4
>            Reporter: Pavel  Tupitsyn
>            Assignee: Vladimir Ozerov
>            Priority: Critical
>             Fix For: ignite-1.4
>
>
> * when node joins the topology, interop processor is not yet ready (Ignite 
> instance is not created in .Net)
> * When that node receives a remote message listener, 
> UnmanagedCallbacks.MessagingFilterCreate gets called, and it blocks on 
> "_initEvent.Wait()"
> * This blocks whole messaging mechanism, so interop processor initialization 
> can't be completed
> We need to:
> * Override onKernalStart in PlatformProcessorImpl and call platform.onStart 
> from there
> * In .Net, release _initEvent from that callback



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to