https://issues.apache.org/jira/browse/IGNITE-2352?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15159407#comment-15159407
 ] 

Ivan Veselovsky commented on IGNITE-2352:
-----------------------------------------

1) fixed: accessTime is now propagated from the underlying file system as well 
as modificationTime. 
Note however, that 
(a) accessTime in IGFS is not handled as real access time (due to performance 
reasons); 
(b) method org.apache.ignite.IgniteFileSystem#setTimes does not work with dual 
file systems, so the accessTime can be treated as a read-only property 
propagated from underlying file system.
2) fixed.

> IGFS shows incorrect file modification time when running over secondary file 
> system.
> ------------------------------------------------------------------------------------
>
>                 Key: IGNITE-2352
>                 URL: https://issues.apache.org/jira/browse/IGNITE-2352
>             Project: Ignite
>          Issue Type: Bug
>          Components: IGFS
>    Affects Versions: ignite-1.4
>            Reporter: Vladimir Ozerov
>            Assignee: Ivan Veselovsky
>            Priority: Critical
>              Labels: important
>             Fix For: 1.6
>
>
> Steps to reproduce:
> 1) Create a file in a secondary file system.
> 2) Access this file directly and observe creation date X.
> 3) Now access this file indirectly through IGFS and observe that it will have 
> different creation date Y. 
> We need to make such properties equal.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to