https://issues.apache.org/jira/browse/IGNITE-13306?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17167164#comment-17167164
]
Denis Mekhanikov commented on IGNITE-13306:
-------------------------------------------
[~ibessonov] there are different possible ways to solve this issue.
One of them is to cast the {{java.lang.management.OperatingSystemMXBean}} to
{{com.sun.management.OperatingSystemMXBean}} and call {{getProcessCpuTime()}}
directly. This way metrics will only work on those JVMs that have
{{com.sun.management.OperatingSystemMXBean}}, which is platform-specific.
Another way is to figure out how to call {{getProcessCpuTime()}} via reflection
without violating any checks. It's possible that there are other
implementations of {{java.lang.management.OperatingSystemMXBean}} that have
this method. But even if you remove the call to {{setAccessible(true)}}, then
the exception will be thrown anyways, since the internal class
{{OperatingSystemImpl}} will be used, even though a public interface is present.
So, I suggest merging this change as a temporary workaround that will work for
most cases, and see how it can be fixed properly in a separate ticket.
> CpuLoad metric return -1 under Java 11
> --------------------------------------
>
> Key: IGNITE-13306
> URL: https://issues.apache.org/jira/browse/IGNITE-13306
> Project: Ignite
> Issue Type: Bug
> Affects Versions: 2.8.1
> Reporter: Mirza Aliev
> Assignee: Mirza Aliev
> Priority: Major
> Fix For: 2.9
>
> Time Spent: 10m
> Remaining Estimate: 0h
>
> Start cluster under Java 11.
> Observed:
> CpuLoad metric will return -1
> Expected:
> Real CpuLoad.
> We investigated this issue and found that under Java 11 code failed with
> following trace:
> {code:java}
> class org.apache.ignite.IgniteException: Failed to get property value
> [property=processCpuTime,
> obj=com.sun.management.internal.OperatingSystemImpl@1dd92fe2] at
> org.apache.ignite.internal.util.IgniteUtils.property(IgniteUtils.java:8306)
> at
> org.apache.ignite.internal.managers.discovery.GridDiscoveryManager$MetricsUpdater.getCpuLoad(GridDiscoveryManager.java:3131)
> at
> org.apache.ignite.internal.managers.discovery.GridDiscoveryManager$MetricsUpdater.run(GridDiscoveryManager.java:3093)
> at
> org.apache.ignite.internal.processors.timeout.GridTimeoutProcessor$CancelableTask.onTimeout(GridTimeoutProcessor.java:364)
> at
> org.apache.ignite.internal.processors.timeout.GridTimeoutProcessor$TimeoutWorker.body(GridTimeoutProcessor.java:233)
> at
> org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:119) at
> java.base/java.lang.Thread.run(Thread.java:834) Caused by:
> java.lang.reflect.InaccessibleObjectException: Unable to make public long
> com.sun.management.internal.OperatingSystemImpl.getProcessCpuTime()
> accessible: module jdk.management does not "opens
> com.sun.management.internal" to unnamed module @35fb3008 at
> java.base/java.lang.reflect.AccessibleObject.checkCanSetAccessible(AccessibleObject.java:340)
> at
> java.base/java.lang.reflect.AccessibleObject.checkCanSetAccessible(AccessibleObject.java:280)
> at java.base/java.lang.reflect.Method.checkCanSetAccessible(Method.java:198)
> at java.base/java.lang.reflect.Method.setAccessible(Method.java:192) at
> org.apache.ignite.internal.util.IgniteUtils.property(IgniteUtils.java:8297)
> ... 6 more
> {code}
> Under Java 8 metric has expected value.
>
> Solution:
> The behaviour is expected because in Java 11 the CPU load metrics is moved to
> JDK internal module which is not accessible by default. Adding the following
> line to the jvm in which Ignite node is started should solve the issue:
> {noformat}
> --add-opens jdk.management/com.sun.management.internal=ALL-UNNAMED{noformat}
--
This message was sent by Atlassian Jira
(v8.3.4#803005)