https://issues.apache.org/jira/browse/IGNITE-13374?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17303399#comment-17303399
 ] 

Alexander Lapin commented on IGNITE-13374:
------------------------------------------

[~sk0x50]Could you please review the ticket?

> Initial PME hangs because of multiple blinking nodes
> ----------------------------------------------------
>
>                 Key: IGNITE-13374
>                 URL: https://issues.apache.org/jira/browse/IGNITE-13374
>             Project: Ignite
>          Issue Type: Bug
>            Reporter: Alexander Lapin
>            Assignee: Alexander Lapin
>            Priority: Major
>          Time Spent: 20m
>  Remaining Estimate: 0h
>
> *Root cause* of the issue is a race inside GridDhtPartitionsExchangeFuture on 
> client side between two processes:
>  # When old coordinator fails and the new one takes over it sends 
> GridDhtPartitionsSingleRequest messages to all nodes including clients to 
> restore exchange results. Processing this message on client includes updating 
> current coordinator reference (crd field).
>  # When future receives discovery notification about old coordinator failure 
> it should detect change of coordinator and send 
> GridDhtPartitionsSingleMessage to new coordinator to obtain affinity. But 
> updated crd field prevents client from detecting coordinator failure and 
> sending SingleMessage to new coordinator which in turn leads to hanging 
> client.



--
This message was sent by Atlassian Jira