https://issues.apache.org/jira/browse/IGNITE-2942?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15242722#comment-15242722
 ] 

Alexei Scherbakov commented on IGNITE-2942:
-------------------------------------------

The task is about to be finished. Waiting for TC results right now.

Ignite context currently uses method getOrStart which was added as requested in 
IGNITE-2941.
In addition to that, I found some other issues.

1) JavaIgniteContext had no option to be used in embedded mode.
Flag "client" was not available in the constructor. Added it.

2) Added option to stop all Ignite instances from the driver program.
IgniteContext.close(shutdownIgniteOnWorkers: Boolean = false)
Has no effect on workers

3) There was no test for embedded mode Spark integration.
Added JavaEmbeddedIgniteRDDSelfTest.
The main idea of test is to start Spark in local workers mode, run Ignite on
worker threads ( each thread uses it's own grid instance ), do some grid 
operations,
shutdown Ignite on workers and the spark context afterwards.

> Use getOrStart in IgniteContext instead of current try-catch structure
> ----------------------------------------------------------------------
>
>                 Key: IGNITE-2942
>                 URL: https://issues.apache.org/jira/browse/IGNITE-2942
>             Project: Ignite
>          Issue Type: Bug
>          Components: Ignite RDD
>    Affects Versions: 1.5.0.final
>            Reporter: Alexey Goncharuk
>            Assignee: Alexei Scherbakov
>
> IgniteContext initialization code will throw an IgniteIllegalStateException 
> in a case when configuration is invalid: start() will throw an exception, 
> exception is caught and, assuming that Ignite instance is already started, 
> Ignition.ignite() is called again.
> Need to use getOrStart() method instead.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to