Pavel Tupitsyn created IGNITE-18845:
---------------------------------------

             Summary: .NET: Thin 3.0: TestCustomColocationKey is flaky
                 Key: IGNITE-18845
                 URL: https://issues.apache.org/jira/browse/IGNITE-18845
             Project: Ignite
          Issue Type: Improvement
          Components: platforms, thin client
            Reporter: Pavel Tupitsyn
            Assignee: Pavel Tupitsyn


{code}
Expected is <Apache.Ignite.Internal.Proto.ClientOp[1]>, actual is 
<System.Collections.Generic.List`1[Apache.Ignite.Internal.Proto.ClientOp]> with 
0 elements
  Values differ at index [0]
  Missing:  < TupleUpsert >
   at Apache.Ignite.Tests.PartitionAwarenessTests.AssertOpOnNode(Func`1 action, 
ClientOp op, FakeServer node, FakeServer node2, Boolean allowExtraOps) in 
/opt/buildagent/work/b8d4df1365f1f1e5/modules/platforms/dotnet/Apache.Ignite.Tests/PartitionAwarenessTests.cs:line
 352
   at 
Apache.Ignite.Tests.PartitionAwarenessTests.<>c__DisplayClass13_0.<<TestCustomColocationKey>g__Test|0>d.MoveNext()
 in 
/opt/buildagent/work/b8d4df1365f1f1e5/modules/platforms/dotnet/Apache.Ignite.Tests/PartitionAwarenessTests.cs:line
 297
--- End of stack trace from previous location ---
   at Apache.Ignite.Tests.PartitionAwarenessTests.TestCustomColocationKey() in 
/opt/buildagent/work/b8d4df1365f1f1e5/modules/platforms/dotnet/Apache.Ignite.Tests/PartitionAwarenessTests.cs:line
 293
   at 
NUnit.Framework.Internal.TaskAwaitAdapter.GenericAdapter`1.BlockUntilCompleted()
   at 
NUnit.Framework.Internal.MessagePumpStrategy.NoMessagePumpStrategy.WaitForCompletion(AwaitAdapter
 awaiter)
   at NUnit.Framework.Internal.AsyncToSyncAdapter.Await(Func`1 invoke)
   at 
NUnit.Framework.Internal.Commands.TestMethodCommand.RunTestMethod(TestExecutionContext
 context)
   at 
NUnit.Framework.Internal.Commands.TestMethodCommand.Execute(TestExecutionContext
 context)
   at 
NUnit.Framework.Internal.Commands.BeforeAndAfterTestCommand.<>c__DisplayClass1_0.<Execute>b__0()
   at 
NUnit.Framework.Internal.Commands.DelegatingTestCommand.RunTestMethodInThreadAbortSafeZone(TestExecutionContext
 context, Action action)
1)    at Apache.Ignite.Tests.PartitionAwarenessTests.AssertOpOnNode(Func`1 
action, ClientOp op, FakeServer node, FakeServer node2, Boolean allowExtraOps) 
in 
/opt/buildagent/work/b8d4df1365f1f1e5/modules/platforms/dotnet/Apache.Ignite.Tests/PartitionAwarenessTests.cs:line
 352
{code}



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to