https://issues.apache.org/jira/browse/IGNITE-26876?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Pavel Tupitsyn resolved IGNITE-26876.
-------------------------------------
    Resolution: Won't Fix

> .NET: Thin 3.0: Flaky DefaultPort tests
> ---------------------------------------
>
>                 Key: IGNITE-26876
>                 URL: https://issues.apache.org/jira/browse/IGNITE-26876
>             Project: Ignite
>          Issue Type: Bug
>          Components: platforms ai3, thin clients ai3
>            Reporter: Pavel Tupitsyn
>            Assignee: Pavel Tupitsyn
>            Priority: Major
>              Labels: MakeTeamcityGreenAgain, ignite-3
>
> {code}
> System.Net.Sockets.SocketException : Address already in use
>    at 
> System.Net.Sockets.Socket.UpdateStatusAfterSocketErrorAndThrowException(SocketError
>  error, Boolean disconnectOnFailure, String callerName)
>    at System.Net.Sockets.Socket.DoBind(EndPoint endPointSnapshot, 
> SocketAddress socketAddress)
>    at System.Net.Sockets.Socket.Bind(EndPoint localEP)
>    at Apache.Ignite.Tests.IgniteServerBase..ctor(Int32 port) in 
> /opt/buildagent/work/20b0d84335ec07af/gridgain-9/modules/platforms/dotnet/Apache.Ignite.Tests/IgniteServerBase.cs:line
>  42
>    at Apache.Ignite.Tests.FakeServer..ctor(Func`2 shouldDropConnection, 
> String nodeName, Boolean disableOpsTracking, Int32 port) in 
> /opt/buildagent/work/20b0d84335ec07af/gridgain-9/modules/platforms/dotnet/Apache.Ignite.Tests/FakeServer.cs:line
>  78
>    at Apache.Ignite.Tests.ConnectionTests.TestConnectToIpDefaultPort() in 
> /opt/buildagent/work/20b0d84335ec07af/gridgain-9/modules/platforms/dotnet/Apache.Ignite.Tests/ConnectionTests.cs:line
>  40
> {code}
> This leads to buffer leaks which cause failures in other tests.
> The problem is we are trying to test the default port, but it might be 
> occupied due to infra issues.



--
This message was sent by Atlassian Jira