https://issues.apache.org/jira/browse/IGNITE-4111?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Alexandr Kuramshin reassigned IGNITE-4111:
------------------------------------------

    Assignee: Semen Boikov  (was: Alexandr Kuramshin)

> Communication fails to send message if target node did not finish join process
> ------------------------------------------------------------------------------
>
>                 Key: IGNITE-4111
>                 URL: https://issues.apache.org/jira/browse/IGNITE-4111
>             Project: Ignite
>          Issue Type: Bug
>          Components: general
>            Reporter: Semen Boikov
>            Assignee: Semen Boikov
>             Fix For: 2.0
>
>         Attachments: test onFirstMessage hang.log
>
>
> Currently this scenario is possible:
> - joining node sent join request and waits for 
> TcpDiscoveryNodeAddFinishedMessage inside ServerImpl.joinTopology
> - others nodes already see this node and can send messages to it (for example 
> try to run compute job on this node)
> - joining node can not receive message: TcpCommunicationSpi will hang inside 
> 'onFirstMessage' on 'getSpiContext' call, so sending node will get error 
> trying to establish connection
> Possible fix: if in onFirstMessage() spi context is not available, then 
> TcpCommunicationSpi  should send special response which indicates that this 
> node is not ready yet, and sender should retry after some time.
> Also need check internal code for places where message can be unnecessarily 
> sent to node: one such place is 
> GridCachePartitionExchangeManager.refreshPartitions - message is sent to all 
> known nodes, but here we can filter by node order / finished exchage version.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to