Sergey Chugunov created IGNITE-7506:
---------------------------------------
Summary: GridClusterStateProcessor#compatibilityMode flag never
gets reset to false
Key: IGNITE-7506
URL: https://issues.apache.org/jira/browse/IGNITE-7506
Project: Ignite
Issue Type: Bug
Reporter: Sergey Chugunov
Assignee: Sergey Chugunov
When Ignite node of version 2.4+ joins cluster with older versions of Ignite
running it sets *compatibilityMode* flag to handle **cluster state in a special
way (excluding BaselineTopology from discovery exchange process and so on).
But when all old nodes are turned off there is no way except full cluster
restart to enable setting very first **BaselineTopology.
This should be addressed and some way to exit compatibilityMode without full
cluster restart should be provided.
--