https://issues.apache.org/jira/browse/IGNITE-10263?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Andrew Mashenkov updated IGNITE-10263:
--------------------------------------
Labels: Hanging (was: )
> MVCC: Concurrent cache stop can cause vacuum failure.
> -----------------------------------------------------
>
> Key: IGNITE-10263
> URL: https://issues.apache.org/jira/browse/IGNITE-10263
> Project: Ignite
> Issue Type: Bug
> Components: cache, mvcc
> Reporter: Andrew Mashenkov
> Priority: Critical
> Labels: Hanging
>
> The issue can be easily reproduced with IgniteCacheIncrementTxTest in Mvcc
> mode.
>
> Vacuum.cleanup() fails on cctx.gate().enter() if cache is stopped
> concurrently.
> ctx.gate().enter() method fails with IllegalStateException right after
> readLock has been taken.
> So, this lock will be never released and prevent writeLock being taken on
> node stop.
> Replacing enter() with enterIfNotStopped() resolves the issue, but most
> likely we should release readLock on failure inside gateway.enter().
--
This message was sent by Atlassian JIRA